Skip to content
Saved
Menu

Stud Calculator

Count studs and plates from wall length, on-center spacing, corners, and openings. Shopping estimate, not a structural design.

18 studs to buy · 4 plate boards

Shopping estimate only. Stud layout and plate counts are for planning purchases. This is not a structural design: it does not determine whether a wall is load-bearing, size headers or beams, or replace plans, engineering, or local code review.

Wall

1 to 200 feet along this wall segment.

On-center spacing
Stud size
Openings

0 of 20 rows

    Advanced — openings
    Advanced — layout
    Plates
    Header stock
    Prices and board feet

    Results

    Studs to buy
    18
    Full-height studs
    16
    Jack studs
    0
    Cripples (estimate)
    0
    Plate lumber (LF)
    60
    Plate boards
    4
    Header stock (LF)
    0
    Board feet total
    135.29

    Stud purchase length: 7' 8-5/8"

    Layout breakdown
    Layout studs
    16
    Removed for openings
    0
    Layout net
    16
    Corner extras
    0
    Intersection extras
    0
    King studs
    0
    Full-height count
    16
    Jack studs
    0
    Stud pieces before waste
    16
    Cripples (estimate)
    0
    Studs to buy
    18
    Stud waste
    10%

    Shopping list

    Lumber

    Lumber
    ItemSpecQty
    Studs2x47' 8-5/8"Includes jacks and waste18 pc
    Wall plates2x416' 0"4 pc

    How to measure

    Measure the wall length along the plates, including the width of every door and window in that run. On-center spacing is the distance from the center of one stud to the center of the next, not the clear gap between them. Pick 16 inches unless the plan says 12, 19.2, or 24. The layout count already includes a stud at each end. Extra corner studs are only the pieces added beyond those end studs. A three-stud corner at both ends is two corners with two extra studs each.

    For each opening, enter the rough width. The calculator removes about one layout stud per spacing that fits in that width, then adds king studs and jack studs back. It does not know where the opening sits, so two openings can claim the same stud. Precut studs for a nominal 8 foot wall are 92 and 5/8 inches long. A custom height subtracts the plate thickness from the finished wall height instead. This page counts pieces to buy. It does not decide whether the wall carries a load or what header size to use.

    Formula

    Layout studs are the wall length divided by the on-center spacing, rounded up, plus one for the ends. Each opening removes the spacing count rounded down, then adds kings and jacks on both sides. Corner and intersection extras come next. Jacks are bought as full-length studs. Waste applies only to that stud count, then the result is rounded up. Cripples match the removed studs: above a door, and above and below a window. They stay off the buy count unless you include them. Plate feet are wall length times the plate layers. Boards round up the combined plate feet once for walls that share a stock length. Header feet add bearing and have no cross-section. Board feet use nominal 2 by 4 or 2 by 6 sizes.

    A 12 foot wall at 16 inch spacing, with no openings and no extra corners, has 10 layout studs. At 0 percent waste the buy count is 10 studs. At the default 10 percent waste the buy count is 11 studs.

    Common mistakes

    • Forgetting the extra stud at the end of the wall.
    • Using the clear gap between studs as the on-center spacing.
    • Subtracting an opening and not adding the king and jack studs back.
    • Using this page to decide if a wall is load-bearing or to size a header.
    • Counting a shared corner on both walls. Extra corner studs belong to one wall only.

    A 12 foot wall is 10 layout studs, and a 20 foot wall with one 36 inch door is 20 studs to buy at 10 percent waste. Both counts are in the stud count guide.

    FAQ

    How many studs do I need for a 20 foot wall at 16 inch spacing?

    A 20 foot wall at 16 inch on-center spacing has 16 layout studs when there is no opening and no extra corner. That is the length divided by the spacing, rounded up, plus one stud for the far end. At the default 10 percent waste the buy count is 18 studs. A door or window takes layout studs out and puts king and jack studs back. Those counts are for a shopping list, not a framing plan.

    What does on-center mean?

    On-center means the distance from the center of one stud to the center of the next. It is not the clear gap between the faces of the studs. The first stud sits at the start of the wall and the last sits at the end, so the count is one more than the number of spaces. When the length is not an even multiple of the spacing, the last space is shorter and the end stud is still included.

    Do I need double top plates?

    The default is two top plates and one bottom plate, so plate feet are three times the wall length. That matches a common exterior or bearing-wall shopping list. It does not mean this tool has decided the wall is load-bearing. You can set one top plate. Precut stud lengths stay at the store length when you do that. Switch to a custom wall height if the stud length should shrink or grow with the plates you entered.

    How are doors and windows counted?

    Each opening removes about as many layout studs as fit in its width at the chosen spacing, using round-down. A king stud and a jack stud are then added on each side, and you can change that count. The kings are full height. The jacks are shorter, but the buy count still treats them as whole studs. Cripples are listed separately and stay off the buy count unless you turn that option on.

    Is this code-approved framing?

    No. The results are a shopping estimate for studs, plates, and header length. The page does not decide if a wall is load-bearing, does not choose a header size, and does not check local code. Header output is length only, using the jack thickness as a default bearing. Use the plans, the applicable code, and a qualified builder or engineer before you frame. The diagram is schematic and does not locate openings.

    What is the difference between a 92-5/8 inch precut and an 8 foot stud?

    A precut stud for a nominal 8 foot wall is 92 and 5/8 inches long. With a 1.5 inch bottom plate and two 1.5 inch top plates, the assembled wall is about 97 and 1/8 inches. This page does not shorten that precut to 91.5 inches. Choose a custom 8 foot height when the stud should be the wall height minus the plates. Those two lengths are both available, and they are not the same board.

    Browse lumber calculators

    By Lumber Calc Editorial Team · Checked against the 2021 IRC & AWC DCA 6 · 2024 sections not yet verified · Last updated Nov 4, 2026